Marinas, Boatyards, and Docking Facilities
Governs the electrical supply to docks and boats, driven hard by the danger of electric shock drowning, with leakage-current protection and strict bonding of the wet structure.
Why this code exists
A small leakage current into fresh water can paralyze a swimmer and drown them without ever leaving a mark, so marina rules chase tiny faults relentlessly.
Article 555 is dominated by electric shock drowning, ESD, where current leaking from a boat or a dock into fresh water passes through a swimmer and stops their muscles. The Code responds with ground-fault protection set to trip at low leakage levels for the feeders and receptacles serving docks, plus thorough bonding of all the metal that makes up the pier.
I test the leakage on these systems and take a nuisance trip as information, not an annoyance, because it may be telling me a boat on the dock is bleeding current into the water. Between the corrosive environment and the swimmers, a marina is one of the few places where a milliamp genuinely decides whether someone lives.
When it applies
This governs power to docks, piers and boats. It is written around a deadly hazard: electric shock drowning, where stray current in the water paralyzes a swimmer. The article calls for leakage-current protection on the supply and thorough bonding of the metal parts of the wet structure so voltage cannot build up in the water.
Common mistakes
- Skipping the ground-fault or leakage protection that trips before a dangerous current reaches the water.
- Leaving dock metalwork unbonded so a fault energizes the structure and the water around it.
- Using standard indoor-grade equipment where the salt, spray and constant damp demand corrosion-rated gear.
In the field
Around water I treat leakage-current protection as non-negotiable and I test it. Electric shock drowning gives no warning and leaves no mark, so a swimmer never knows the water is charged until it is too late — the protection has to catch the fault they cannot feel coming.
At a marina a milliamp into the water can drown a swimmer with no warning. When the ground-fault device trips I treat it as evidence, not a nuisance, because usually a boat is quietly leaking current into the lake.
See full history
- 1978 — Marina and boatyard article established.
- 2017 — Ground-fault protection thresholds tightened to combat electric shock drowning.
Related codes
Open interactive version →Codex is an independent educational reference. Not the National Electrical Code® and not affiliated with the NFPA. Always verify against the adopted code and your AHJ. · Privacy