Floating Buildings
Applies to buildings that float on water and are supplied from shore, addressing the service, feeder, grounding, and bonding challenges of a structure that moves and sits in a conductive environment.
Why this code exists
A floating structure cannot use a normal ground rod in the earth, and surrounding water turns any fault into a shock hazard for swimmers as well as occupants.
Article 553 handles a structure that is a building in every functional way but has no soil to bond to. The grounding scheme relies on an insulated equipment grounding conductor run back to shore rather than a local electrode, and the feeder connection has to tolerate the constant motion of the float without fatiguing or losing continuity.
The service and feeder thinking is what carries this article. You are extending shore power across a flexing gangway to a moving load, so I plan the feeder route, the strain relief, and above all the grounding continuity so a fault always has a low-impedance path home, not a path through the water.
When it applies
Article 553 deals with buildings that actually float on water and get their power from shore. You are wiring a structure that moves, rides swells, and sits surrounded by a conductive medium, so the service, the feeder, and especially the grounding and bonding have to account for all of that. The connections have to tolerate motion without loosening or chafing.
Common mistakes
- Running rigid feeder connections that a moving structure will slowly work apart.
- Getting the grounding and bonding wrong, which around water is a direct path to a shock hazard.
- Ignoring the corrosive marine environment when picking materials.
In the field
On a floating structure the grounding is where I spend my attention, because you have got a moving building over water and no margin for a loose bond. Get the bonding right and flexible, and the rest of the install falls into line.
There is no ground rod in the water, so the grounding conductor back to shore is everything. I run the feeder with real strain relief across the gangway and make sure a fault always has a copper path home instead of the lake.
See full history
- 1978 — Floating building article added to address water-borne structures.
- 2005 — Grounding and bonding provisions coordinated with marina rules.