Stand-Alone Systems
Power systems that run a building entirely off-grid — solar, battery, generator — with no permanent utility connection.
Why this code exists
An off-grid house has no utility to lean on, so the source itself has to handle every fault and every surge. These systems needed their own clear rules instead of borrowing bits from the grid-tied articles.
Article 710 gathers the requirements for stand-alone (off-grid) power systems in one place. These are premises supplied only by their own generation and storage — remote cabins, rural homes, telecom huts, anywhere the utility simply isn't. It grew out of scattered provisions in the solar and interconnection articles as fully off-grid installs became common.
Key points: the supply output must be able to handle the largest single load that could start, plus rules on sizing the inverter to the calculated load, allowing an inverter output rating in place of a conventional service calculation. It addresses back-fed and multi-source arrangements, disconnects, and the fact that an off-grid inverter can be the sole source — so its overcurrent behavior and grounding matter more than usual. It reads as the off-grid companion to Article 705's grid-tied focus.
When it applies
Article 710 covers stand-alone systems, installations that power a structure entirely without a permanent utility connection. Think a remote cabin or off-grid property running on PV, batteries, and maybe a generator, where your sources have to carry the whole load on their own.
Common mistakes
- Sizing the inverter output circuit below the largest single load the system must actually start and run.
- Forgetting that with no utility backing you up, source and storage capacity has to be planned for real peak demand, not average.
- Neglecting a clear means to shut down and service the power source safely.
In the field
On an off-grid cabin I had to remind the owner there is no grid to lean on when the well pump and the fridge both kick on at once. The inverter and battery bank have to swing that combined surge alone. I sized the output circuit to the largest load the system supplies and built in headroom for simultaneous starts. Stand-alone means your design is the only safety net; there is no utility to cover a shortfall.
Off-grid, the inverter IS your service, so I size it to actually start the well pump and the AC compressor at the same time — inrush will humble you fast out at a cabin with no grid to soak it up. And I still bond and ground it properly; being off-grid doesn't make a ground fault any less deadly.
See full history
- 2017 — Stand-alone provisions consolidated into a dedicated article.
- 2020 — Sizing and inverter-output allowances clarified.
Related codes
Open interactive version →Codex is an independent educational reference. Not the National Electrical Code® and not affiliated with the NFPA. Always verify against the adopted code and your AHJ. · Privacy