Concealed Knob-and-Tube Wiring
The earliest standardized wiring method — single conductors on ceramic knobs and through ceramic tubes — now largely historical.
Why this code exists
K&T relied on open air to cool its conductors; when later homeowners buried it in insulation, that cooling vanished and fire risk climbed — so its use is now tightly restricted.
Knob-and-tube was how America's early electrified homes were wired: individual conductors held away from framing on porcelain knobs and passed through porcelain tubes where they crossed wood. The generous air space around each wire was the whole cooling strategy, and there was no equipment-grounding conductor.
The article now mostly governs existing K&T and its limited extension. The great danger is thermal insulation: when homeowners later blow insulation into walls and attics, it smothers conductors designed to breathe, so the Code prohibits covering K&T with insulation. It's rarely installed new and any work on it demands care and, often, replacement.
When it applies
You mostly meet knob-and-tube on old work, not new. Single conductors ride on ceramic knobs and pass through ceramic tubes, kept spaced apart and away from framing. New installations are extremely limited, so in practice this article guides how you evaluate, extend or retire what is already in a house.
Common mistakes
- Burying old knob-and-tube in blown-in insulation, which traps heat around conductors that were designed to shed it into open air.
- Tapping modern circuits onto brittle, cloth-insulated legacy wiring instead of replacing the run.
- Assuming it is grounded — these systems have no equipment grounding conductor.
In the field
When I open a wall and find knob-and-tube packed in insulation, that is a red flag I document immediately. The wiring may have been fine in free air a century ago, but smothered in insulation it runs hot, and hot old insulation is how these fires start.
When I open a wall in an old house and see knobs and tubes, I slow way down. It can still be safe if it's undisturbed and uncovered, but the moment someone packed insulation around it, the clock started ticking. There's no ground either, so any circuit I extend gets brought up to modern wiring, not spliced back into the old system.
See full history
- 1937 — Codified from the earliest wiring practice.
- 1987 — Prohibited from being covered by thermal insulation.
Related codes
Open interactive version →Codex is an independent educational reference. Not the National Electrical Code® and not affiliated with the NFPA. Always verify against the adopted code and your AHJ. · Privacy