334

Nonmetallic-Sheathed Cable (NM)

'Romex' rules: where NM cable may be used, how it's secured and protected from physical damage.

Introduced
1926
Level
NEC (National)
Why this code exists
Fire hazard
Current status
Active

Why this code exists

Cheap, easy NM cable spread quickly; without rules on support, protection and ampacity it became a fire risk.

Article 334 limits NM cable to specific occupancies, requires securing within 12 in of boxes and every 4.5 ft, and derates its conductors to the 60 °C column.

When it applies

NM cable, what everyone calls Romex, is the workhorse of dry, indoor residential wiring. You will run it inside stud bays and above ceilings in most homes. What it is not built for is exposure to moisture, direct sunlight, or spots where it can get knocked around, so it stays inside the protected structure of the building.

Common mistakes

In the field

When I fish NM through an unfinished basement, I keep it stapled neatly up along the joists and never let it dangle where a stored ladder or bike could rub through the jacket over time.

Field note
Romex is fast, which is exactly why people get sloppy — unsupported runs, no protection through studs. Secure it right and it'll outlast the house.
— Priya · Journeyman · 12 yrs